Faults and solutions in the blowing process of the bottle blowing machine

1. High temperature alarm for light box water channel.

Solution: Disassemble the rubber tube connected to the water channel, and use low-pressure air and alcohol to purge and clean the water channel.


2. Gripper failure

Solution: Adjust the height of the sliding table or the position of the gripper.


3. The action is stuck.

Solution: restart the machine.


4. Cannot manually origin

Solution: Check whether the shifting of the first gripper, the shifting of the second gripper and the variable pitch positioning plate is stuck to the corresponding position, if not, manually make them stuck to the corresponding position, and then the origin.


5. The action is not in place

Solution: Check if there is something stuck. Adjust the gas flow valve.


6. Exhaust sound is too loud

Solution: Check whether the high-pressure exhaust muffler is damaged or falling off. 